C_SaveSimulationMem |
Call C_SaveSimulationMem to save an OrcaFlex simulation to memory.
void C_SaveSimulationMem(
);
The handle of the model.
Points to a variable in which a handle to the saved buffer will be returned.
Points to a variable in which the length of the saved buffer will be returned.
Points to a variable in which the status result for the function call will be returned.
In order to extract the contents of the buffer, you must follow the call to C_SaveSimulationMem with calls to C_CopyBuffer and C_FreeBuffer. Use the value returned in lpBufferLen to allocate a suitably sized buffer. Pass this to C_CopyBuffer to perform the copy. Finally, call C_FreeBuffer to free the buffer handle.
Such code typically looks like this:
TOrcFxAPIHandle BufferHandle;
int64_t BufferLen;
int Status;
C_SaveSimulationMem(ModelHandle, &BufferHandle, &BufferLen, &Status);
unsigned char *lpBuffer = new unsigned char[BufferLen];
C_CopyBuffer(BufferHandle, lpBuffer, BufferLen, &Status);
C_FreeBuffer(BufferHandle, &Status);
// use lpBuffer
delete[] lpBuffer;
Note that, for the sake of brevity, error checking has been omitted from the above code.
C_CopyBuffer, C_FreeBuffer, C_LoadDataMem, C_LoadSimulationMem, C_SaveDataMem, C_SaveSimulation.